CFS-BL firestop block
Firestop block CFS-BL #2062863
Preformed firestop blocks for sealing penetrations with cables
- Dimensions (LxWxH): 200 x 130 x 50 mm
- Base materials: Concrete, Masonry, Gypsum board, Sandwich Panel, Multi
- Storage and transportation temperature range: -5 - 40 °C
Technical Data
Documents
Features & Applications
Features
- Easy to install – no power tools required
- Easy maintenance and possible retrofitting of cables
- Economical installation – firestop blocks arrive pre-cured and ready-to-use
- Fibre-, halogen- and solvent-free
- Virtually dust-free (depending on the installation method)
Applications
- Temporary or permanent passive fire sealing around cables, cable bundles and cable trays in wall and floor openings
- Firestopping penetrations for cables, cable bundles and cable trays
- Firestopping penetrations for conduits and conduit bundles
- Firestopping penetrations for co-axial cables
- Optimal for rooms with dust- and fibre-free requirements and areas with frequent retrofitting, such as server rooms, laboratories and hospitals
Consulting & Support
Information: We will contact you about the product demo request within 1 business day(request before 6:00pm).
Information: Only available during business hours from Mon - Fri: 08:30 - 17:00
Information: Only available during business hours from Mon - Fri: 08:30 - 17:00
FIRESTOP CABLE PATHWAY IMPROVES AIRFLOW MANAGEMENT
Save on operating expenses with the Hilti speed sleeve
As the demand for data centers continues to skyrocket, the industry has started focusing on solutions to improve energy efficiency – reducing operating costs and carbon emissions. Airflow management has emerged as a primary method of reducing energy consumption.
Nearly all airflow management practices require an airtight envelope to prevent bypass and turbulence. But constant cabling updates often compromise perimeter walls when firestopping materials aren’t properly replaced.
The innovative twist mechanism of the Hilti firestop speed sleeve not only allows for effortless cabling updates, but also provides excellent airflow control.
PROVEN AIRFLOW CONTROL
Tested leakage ratings for use in design simulations
The leakage of our speed sleeve cable pathway was tested to internationally recognized standards such as UL 1479 and EN 1026. The extensive third-party testing confirmed the sleeve’s superior airflow control at a variety of fill ratios and a wide range of operating pressures.
Whether you’re looking for leakage data for design simulations or pressure-resistance data for gaseous fire suppression systems, we have the information you need to ensure the efficiency and reliability of your design.